| Stroke length |
|---|
Product safety
Safety instructions
Read all safety warnings, instructions, illustrations and technical data in this product carefully. Failure to observe the following operating instructions can lead to electric shock, fire and / or serious injury. Save all warnings and instructions for future Reference.
Intended Use
– Designed for Opening and Closing the Windows and louvers on the building facades and roofs
– Operating voltage: 24 V DC (-15 %/+25 %)
– Suitable for smoke extraction and daily comfort ventilation
– Only for indoor installation
Scope of delivery
Chain drive
– Different console component are available as optional accessories for specific types of Windows available.
Requirements for qualification of personnel
All installation, wiring, commissioning and maintenance of window actuators may only be operated by trained and qualified personnel. Untrained personnel access to all areas of the Work is strictly prohibited.
Pre-installation and Device selection
– Turn on the window-opener, to check it for any transit damage
– Make sure that the load capacity of the selected model corresponds to the actual window weight and wind pressure, and thus, all of the operating requirements
– Check the stability of the window frame and the hinges to ensure that you keep the operating loads
– Always use Original mounting brackets and fasteners. For aluminium window frames, rivets, or
Through-bolts are recommended
self-cutting should be avoided screws
Requirements for electrical safety
– Power window actuator needs to ensure a stable operating voltage of 24 V DC (-15 %/+25%).
Voltage fluctuations outside of this range can Board the device to malfunction or damage to the control
lead
– Use according to the technical standard is sufficiently dimensioned cable to minimize voltage drop.
Intended Use
– The control unit should have an automatic shut-off function, which is activated as soon as the chain-drive its fully
open Position has been reached. As a result, the power supply is interrupted at the end of the Stroke
– Before cleaning, maintenance or Troubleshooting of the main power supply to work, always disconnect
Safety precautions for the Installation
– For Windows, which are installed in a height of 2.5 meters, must be reliable anti-trap devices. In
public areas should also be an infrared safety sensor installed. For floor-standing window safety ropes are
and fall protection is required
– All automatic Windows, must wear a clearly visible place a clearly visible warning "risk of entrapment"
– Keep the operating area of the window is clear of obstacles. Manual controls must be installed so that the
Movement of the window can be directly observed
Maintenance and cleaning
– All maintenance work must be carried out in completely the device is switched off.
– A routine Review of the power cable and rails should be done at least once a year. The detection of
Abnormalities discontinue use immediately. Repairs may only parts of the AF-certified technicians using original
be carried out. Unauthorized disassembly is strictly prohibited.
– Use a soft, dry cloth to remove any dust or dirt from the surface. Do not use
Cleaning agents or solvents
Technical Data
Auch Siehe Gebrauchsanleitungen in „Downloads“
You need more technical information? Please contact us, we will respond immediately to help!
Downloads
You need more Downloads, installation instructions? Please contact us, we will respond immediately to help!
Scope of delivery
Antrieb VS-SB 400/450-i mit Standard Konsolen