{"id":18329,"date":"2026-11-21T11:40:20","date_gmt":"2026-11-21T10:40:20","guid":{"rendered":"https:\/\/ventsystems.de\/lexikon\/taupunkt\/"},"modified":"2026-11-21T16:24:46","modified_gmt":"2026-11-21T15:24:46","slug":"dew-point","status":"publish","type":"page","link":"https:\/\/ventsystems.de\/en\/lexikon\/taupunkt\/","title":{"rendered":"Dew point"},"content":{"rendered":"<p class=\"wp-block-paragraph\">The <strong>Dew point<\/strong> (dew point temperature) is the temperature to which humid air can cool before water condenses. If a surface \u2013 such as a window pane, a frame or an actuator housing \u2013 is colder than the dew point of the room air, <strong>condensation<\/strong> forms there. The warmer and more humid the air, the higher the dew point.<\/p>\n\n\n\n<div class=\"vs-calc vs-tp\" style=\"background:#f1f6f5;border:1px solid #b0bec5;border-radius:8px;padding:16px;margin:1.5em 0\"><p><strong>Dew point calculator<\/strong><\/p><p><label>Air temperature (\u00b0C) <input type=\"number\" class=\"tp-t\" value=\"30\" step=\"0.5\" style=\"width:90px\"><\/label> <label>Relative humidity (%) <input type=\"number\" class=\"tp-h\" value=\"60\" min=\"1\" max=\"100\" style=\"width:90px\"><\/label><\/p><p>Dew point: <strong class=\"tp-o\">\u2013<\/strong> \u00b0C<\/p><p style=\"font-size:0.85em\">Calculated with the Magnus formula (approximation). Surfaces that are colder will mist up.<\/p><\/div>\n<script>(function(){document.querySelectorAll(\".vs-tp\").forEach(function(b){function c(){var t=parseFloat(b.querySelector(\".tp-t\").value.replace(\",\",\".\")),h=parseFloat(b.querySelector(\".tp-h\").value.replace(\",\",\".\"));if(isNaN(t)||isNaN(h)||h<=0||h>100){b.querySelector(\".tp-o\").textContent=\"\u2013\";return}var a=17.62,k=243.12,g=Math.log(h\/100)+a*t\/(k+t);b.querySelector(\".tp-o\").textContent=(k*g\/(a-g)).toFixed(1)}b.addEventListener(\"input\",c);c()})})();<\/script>\n\n\n\n<figure class=\"vs-video\" style=\"margin:1.5em 0\"><div style=\"position:relative;padding-top:56.25%\"><button type=\"button\" class=\"vs-yt\" onclick=\"this.outerHTML=this.dataset.f\" data-f=\"&lt;iframe src=&quot;https:\/\/www.youtube-nocookie.com\/embed\/dEho05ZM7UE?autoplay=1&quot; title=&quot;Taupunkt in der Schwimmhalle: Warum Fenster beschlagen&quot; allow=&quot;autoplay; encrypted-media; picture-in-picture&quot; allowfullscreen style=&quot;position:absolute;top:0;left:0;width:100%;height:100%;border:0&quot;&gt;&lt;\/iframe&gt;\" style=\"position:absolute;top:0;left:0;width:100%;height:100%;padding:0;border:0;background:#000;cursor:pointer\" aria-label=\"Video abspielen: Taupunkt in der Schwimmhalle: Warum Fenster beschlagen\"><img decoding=\"async\" src=\"https:\/\/i.ytimg.com\/vi\/dEho05ZM7UE\/hqdefault.jpg\" alt=\"Dew point in the pool hall: why windows mist up\" loading=\"lazy\" style=\"width:100%;height:100%;object-fit:cover;display:block;opacity:.9\"><span style=\"position:absolute;left:50%;top:50%;transform:translate(-50%,-50%);background:#c00;color:#fff;border-radius:12px;padding:8px 22px;font-size:22px;line-height:1\">&#9654;<\/span><\/button><\/div><figcaption><strong>Dew point in the pool hall: why windows mist up:<\/strong> Short video: why glass surfaces in the pool hall mist up below the dew point and how targeted ventilation with window actuators helps.<\/figcaption><\/figure><script type=\"application\/ld+json\">{\n    \"@context\": \"https:\\\/\\\/schema.org\",\n    \"@type\": \"VideoObject\",\n    \"name\": \"Taupunkt in der Schwimmhalle: Warum Fenster beschlagen\",\n    \"description\": \"Warme, feuchte Hallenluft trifft auf kalte Glasfl\\u00e4chen: Unter dem Taupunkt kondensiert Wasser, Fenster und Lichtkuppeln beschlagen. Gezielt \\u00f6ffnende Fensterantriebe mit Hygrostat- oder Zeitsteuerung helfen beim L\\u00fcften.\",\n    \"thumbnailUrl\": \"https:\\\/\\\/i.ytimg.com\\\/vi\\\/dEho05ZM7UE\\\/hqdefault.jpg\",\n    \"uploadDate\": \"2026-11-22T12:00:00+01:00\",\n    \"contentUrl\": \"https:\\\/\\\/www.youtube.com\\\/watch?v=dEho05ZM7UE\",\n    \"embedUrl\": \"https:\\\/\\\/www.youtube-nocookie.com\\\/embed\\\/dEho05ZM7UE\",\n    \"publisher\": {\n        \"@type\": \"Organization\",\n        \"name\": \"Vent Systems HDI GmbH\",\n        \"url\": \"https:\\\/\\\/ventsystems.de\\\/\"\n    }\n}<\/script>\n\n\n\n<h2 class=\"wp-block-heading\">Calculation examples: dew point of room air<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Room air<\/th><th>relative humidity<\/th><th>Dew point (approx.)<\/th><th>typical location<\/th><\/tr><\/thead><tbody><tr><td>20 \u00b0C<\/td><td>50 %<\/td><td>9.3 \u00b0C<\/td><td>Flat, office<\/td><\/tr><tr><td>20 \u00b0C<\/td><td>60 %<\/td><td>12.0 \u00b0C<\/td><td>Classroom at full occupancy<\/td><\/tr><tr><td>25 \u00b0C<\/td><td>80 %<\/td><td>21.3 \u00b0C<\/td><td>Shower, changing room<\/td><\/tr><tr><td>30 \u00b0C<\/td><td>55 %<\/td><td>20.0 \u00b0C<\/td><td>Pool hall<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Dew point in the pool hall<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">In pool halls the air is warm and humid. The table shows the surface temperature below which glazing, frames and actuators mist up. Values calculated with the Magnus formula, rounded.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Hall air<\/th><th>50 % RH<\/th><th>55 % RH<\/th><th>60 % RH<\/th><th>64 % RH<\/th><\/tr><\/thead><tbody><tr><td>28 \u00b0C<\/td><td>16.6 \u00b0C<\/td><td>18.1 \u00b0C<\/td><td>19.5 \u00b0C<\/td><td>20.6 \u00b0C<\/td><\/tr><tr><td>30 \u00b0C<\/td><td>18.4 \u00b0C<\/td><td>20.0 \u00b0C<\/td><td>21.4 \u00b0C<\/td><td>22.4 \u00b0C<\/td><\/tr><tr><td>32 \u00b0C<\/td><td>20.3 \u00b0C<\/td><td>21.8 \u00b0C<\/td><td>23.3 \u00b0C<\/td><td>24.3 \u00b0C<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Example: with hall air at 30 \u00b0C and 60 % relative humidity, condensation forms on any surface below about 21 \u00b0C. A ventilation system for dehumidification, warm inner surfaces and controlled ventilation help \u2013 more on this under <a href=\"\/en\/dictionary\/hygrostat\/\">Hygrostat<\/a> and <a href=\"\/en\/window-actuators-indoor-pool\/\">Window actuators for indoor pools<\/a>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Calculated with the Magnus formula (approximation, accurate to about \u00b10.5 \u00b0C). Pool hall example: at 30 \u00b0C and 55 % humidity, every surface colder than about 20 \u00b0C mists up \u2013 in winter, glass, frames and rooflights quickly do.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">What does this mean for windows and window actuators?<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Condensation on windows<\/strong> forms mainly on cold edges of glass and frames and on rooflights.<\/li>\n\n\n<li><strong>Actuators in damp rooms<\/strong> are often located exactly where condensation drips \u2013 pay attention to the protection rating (IP) and the mounting position.<\/li>\n\n\n<li><strong>Ventilating regularly<\/strong> lowers humidity and therefore the dew point; automatic window actuators with timer or humidity control help with this.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Learn more: <a href=\"\/en\/window-actuators-indoor-pool\/\">Window actuators for indoor pools<\/a> \u00b7 <a href=\"\/en\/dictionary\/ip-rating\/\">protection class IP<\/a> \u00b7 <a href=\"\/en\/dictionary\/rooflight\/\">Dome rooflight<\/a>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Source of the formula: Magnus formula according to Sonntag (1990), coefficients 17.62 and 243.12 \u00b0C. Values rounded.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Frequently asked questions<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">How do I calculate the dew point?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">With the Magnus formula from air temperature and relative humidity. The calculator at the top of this page does it for you: at 20 \u00b0C and 50 % relative humidity the dew point is about 9 \u00b0C, at 30 \u00b0C and 60 % about 21 \u00b0C. Surfaces that are colder mist up.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Humidity in buildings:<\/strong> <a href=\"\/en\/dictionary\/dew-point\/\">Dew point<\/a> \u00b7 <a href=\"\/en\/dictionary\/relative-humidity\/\">Relative humidity<\/a> \u00b7 <a href=\"\/en\/dictionary\/absolute-humidity\/\">Absolute humidity<\/a> \u00b7 <a href=\"\/en\/dictionary\/condensation\/\">condensation<\/a> \u00b7 <a href=\"\/en\/dictionary\/hygrostat\/\">Hygrostat<\/a> \u00b7 <a href=\"\/en\/dictionary\/air-change-rate\/\">Air change rate<\/a> \u00b7 <a href=\"\/en\/dictionary\/purge-ventilation\/\">Purge ventilation<\/a><\/p>","protected":false},"excerpt":{"rendered":"<p>Der Taupunkt (Taupunkttemperatur) ist die Temperatur, bis zu der feuchte Luft abk\u00fchlen kann, bevor sich Wasser niederschl\u00e4gt. Ist eine Oberfl\u00e4che \u2013 etwa eine Fensterscheibe, ein Rahmen oder ein Antriebsgeh\u00e4use \u2013 k\u00e4lter als der Taupunkt der Raumluft, bildet sich dort Kondensat (Tauwasser). Je w\u00e4rmer und feuchter die Luft, desto h\u00f6her liegt der Taupunkt. Taupunkt-Rechner Lufttemperatur (\u00b0C) [&hellip;]<\/p>\n","protected":false},"author":9,"featured_media":0,"parent":16230,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-18329","page","type-page","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/ventsystems.de\/en\/wp-json\/wp\/v2\/pages\/18329","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ventsystems.de\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/ventsystems.de\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/ventsystems.de\/en\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/ventsystems.de\/en\/wp-json\/wp\/v2\/comments?post=18329"}],"version-history":[{"count":4,"href":"https:\/\/ventsystems.de\/en\/wp-json\/wp\/v2\/pages\/18329\/revisions"}],"predecessor-version":[{"id":18403,"href":"https:\/\/ventsystems.de\/en\/wp-json\/wp\/v2\/pages\/18329\/revisions\/18403"}],"up":[{"embeddable":true,"href":"https:\/\/ventsystems.de\/en\/wp-json\/wp\/v2\/pages\/16230"}],"wp:attachment":[{"href":"https:\/\/ventsystems.de\/en\/wp-json\/wp\/v2\/media?parent=18329"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}