{"id":12926,"date":"2025-12-07T08:51:31","date_gmt":"2025-12-07T07:51:31","guid":{"rendered":"https:\/\/ventsystems.de\/?p=12926"},"modified":"2026-10-26T12:08:22","modified_gmt":"2026-10-26T11:08:22","slug":"smoke-and-heat-extraction-shev-why-high-quality-drives-are-crucial-in-case-of-fire","status":"publish","type":"post","link":"https:\/\/ventsystems.de\/en\/rauch-und-waermeabzug-rwa-warum-hochwertige-antriebe-im-brandfall-entscheidend-sind\/","title":{"rendered":"Smoke and heat extraction (SHEV): why high-quality drives are critical in the event of a fire"},"content":{"rendered":"<div class=\"et_pb_section_0 et_pb_section et_section_regular et_flex_section\"><div class=\"et_pb_row_0 et_pb_row et_flex_row\"><div class=\"et_pb_column_0 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone\"><div class=\"et_pb_text_0 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module\"><div class=\"et_pb_text_inner\"><p><!-- wp:paragraph --><\/p>\n<p>A functioning smoke and heat extraction system is essential to remove dangerous smoke layers in the event of a fire and to keep escape routes passable. Electrical <a href=\"https:\/\/ventsystems.de\/en\/shop-with-filter\/\">Window drives<\/a> They play a central role here: They open affected windows or skylights automatically and reliably \u2013 even under high load.<\/p>\n<p><strong>In brief:<\/strong> In a smoke and heat exhaust system, the window actuators open the smoke vents in the event of fire \u2013 quickly, reliably and even against wind and snow load. That is why sufficient force, robust technology and regular maintenance matter for RWA actuators.<\/p>\n<p><!-- \/wp:paragraph --><\/p>\n<p><!-- wp:paragraph --><\/p>\n<p>High-quality actuators are more than just mechanics. They must meet clear safety standards and withstand a high number of load cycles. Our models achieve at least 10,000 double strokes under maximum load and are therefore ideally prepared for regular everyday use and emergencies.<\/p>\n<p><!-- \/wp:paragraph --><\/p>\n<p><!-- wp:paragraph --><\/p>\n<p>A coordinated combination of drive, control system, and sensors creates comprehensive smoke and heat exhaust ventilation (SHEV) solutions that offer planning reliability to tradespeople and construction companies. Thanks to our own stock in Hamburg, many common models can be delivered at short notice \u2013 a major advantage for time-critical projects.<\/p>\n<p><!-- \/wp:paragraph --><\/p>\n<p><!-- wp:paragraph --><\/p>\n<p><strong>Suitable products:<\/strong> <a href=\"https:\/\/ventsystems.de\/en\/product\/vs-za-800\/\">VS-ZA 800 rack-and-pinion actuator<\/a> (800 N), <a href=\"https:\/\/ventsystems.de\/en\/product\/vs-la\/\">VS-LA linear actuator<\/a> (600\u20135000 N) and <a href=\"https:\/\/ventsystems.de\/en\/product\/vs-ka\/\">VS-KA chain actuator<\/a> (250\u20131500 N). You can find an overview of all drives in the <a href=\"https:\/\/ventsystems.de\/en\/shop-with-filter\/\">Vent Systems Shop<\/a>.<\/p>\n<p><!-- \/wp:paragraph --><\/p>\n<p><!-- wp:paragraph --><\/p>\n<p>The maintenance and inspection obligations for smoke and heat exhaust systems are explained in the guide <a href=\"\/en\/shev-maintenance-inspection\/\">SHEV maintenance and inspection duties<\/a>.<\/p>\n<p><!-- \/wp:paragraph --><\/p>\n<p><!-- wp:group {\"className\":\"vs-linkbox\"} --><\/p>\n<div class=\"wp-block-group vs-linkbox\"><!-- wp:heading --><\/p>\n<h2 class=\"wp-block-heading\">Frequently asked questions<\/h2>\n<p><!-- \/wp:heading --><\/p>\n<p><!-- wp:heading {\"level\":3} --><\/p>\n<h3 class=\"wp-block-heading\">What is the role of window actuators in a smoke and heat exhaust system?<\/h3>\n<p><!-- \/wp:heading --><\/p>\n<p><!-- wp:paragraph --><\/p>\n<p>In the event of fire, they open the assigned windows or rooflights automatically and reliably \u2013 even under high load \u2013 so that dangerous smoke layers can escape and escape routes remain passable.<\/p>\n<p><!-- \/wp:paragraph --><\/p>\n<p><!-- wp:heading {\"level\":3} --><\/p>\n<h3 class=\"wp-block-heading\">What requirements must a high-quality SHEV actuator meet?<\/h3>\n<p><!-- \/wp:heading --><\/p>\n<p><!-- wp:paragraph --><\/p>\n<p>It must meet the relevant safety standards and withstand a high number of load cycles. Vent Systems actuators achieve at least 10,000 double strokes under maximum load.<\/p>\n<p><!-- \/wp:paragraph --><\/p>\n<p><!-- wp:heading {\"level\":3} --><\/p>\n<h3 class=\"wp-block-heading\">Can SHEV actuators also be used for daily ventilation?<\/h3>\n<p><!-- \/wp:heading --><\/p>\n<p><!-- wp:paragraph --><\/p>\n<p>Yes. Actuators with a high cycle rating are designed for regular everyday use as well as for emergencies. What matters is a well-matched combination of actuator, control unit and sensors.<\/p>\n<p><!-- \/wp:paragraph --><\/p>\n<p><!-- wp:heading --><\/p>\n<h2 class=\"wp-block-heading\">Suitable products at Vent Systems<\/h2>\n<p><!-- \/wp:heading --><\/p>\n<p><!-- wp:list --><\/p>\n<ul class=\"wp-block-list\"><!-- wp:list-item --><\/p>\n<li><a href=\"\/en\/product\/vs-ka\/\">VS-KA chain drive (250\u20131500 N)<\/a><\/li>\n<p><!-- \/wp:list-item --><br \/>\n<!-- wp:list-item --><\/p>\n<li><a href=\"\/en\/product\/vs-la\/\">VS-LA linear actuator<\/a><\/li>\n<p><!-- \/wp:list-item --><br \/>\n<!-- wp:list-item --><\/p>\n<li><a href=\"\/en\/product-category\/chain-drives\/\">All chain drives in the shop<\/a><\/li>\n<p><!-- \/wp:list-item --><\/ul>\n<p><!-- \/wp:list --><\/p>\n<p><!-- wp:paragraph --><\/p>\n<p><strong>Read more:<\/strong> <a href=\"https:\/\/ventsystems.de\/en\/what-is-an-rwa-system-abbreviation-function-and-design\/\">What is a smoke and heat exhaust ventilation system (SHEVS)? Abbreviation, function and structure explained simply.<\/a> \u00b7 <a href=\"https:\/\/ventsystems.de\/en\/rwa-vs-nrwg-what-is-the-difference\/\">RWA vs. NRWG: What is the difference?<\/a><\/p>\n<p><!-- \/wp:paragraph --><\/p>\n<p><!-- wp:paragraph --><\/p>\n<p>Questions about the selection process? <a href=\"\/en\/contact\/\">Contact us<\/a> \u2013 We will advise you on drive systems, controls and accessories.<\/p>\n<p><!-- \/wp:paragraph --><\/div>\n<p><!-- \/wp:group --><\/p>\n<p><!-- wp:paragraph --><\/p>\n<p>An overview of suitable actuators can be found at <a href=\"https:\/\/ventsystems.de\/en\/rwa-drives\/\">Smoke and heat exhaust ventilation (SHEV) drives for windows and skylights<\/a>.<\/p>\n<p><!-- \/wp:paragraph --><\/p>\n<\/div><\/div><\/div><\/div><\/div>\n<p class=\"wp-block-paragraph\"><strong>Read more:<\/strong> <a href=\"\/en\/smoke-vent-stairwell\/\">Smoke Vent in the Stairwell: Requirements, Opening Size and Operation<\/a><\/p>","protected":false},"excerpt":{"rendered":"<p>Weiterlesen: Rauchabzug im Treppenhaus: Pflicht, \u00d6ffnungsgr\u00f6\u00dfe und Bedienung<\/p>","protected":false},"author":9,"featured_media":10814,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1957],"tags":[],"class_list":["post-12926","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-ratgeber-rwa"],"acf":[],"_links":{"self":[{"href":"https:\/\/ventsystems.de\/en\/wp-json\/wp\/v2\/posts\/12926","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ventsystems.de\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/ventsystems.de\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/ventsystems.de\/en\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/ventsystems.de\/en\/wp-json\/wp\/v2\/comments?post=12926"}],"version-history":[{"count":14,"href":"https:\/\/ventsystems.de\/en\/wp-json\/wp\/v2\/posts\/12926\/revisions"}],"predecessor-version":[{"id":16806,"href":"https:\/\/ventsystems.de\/en\/wp-json\/wp\/v2\/posts\/12926\/revisions\/16806"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ventsystems.de\/en\/wp-json\/wp\/v2\/media\/10814"}],"wp:attachment":[{"href":"https:\/\/ventsystems.de\/en\/wp-json\/wp\/v2\/media?parent=12926"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ventsystems.de\/en\/wp-json\/wp\/v2\/categories?post=12926"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ventsystems.de\/en\/wp-json\/wp\/v2\/tags?post=12926"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}