{"id":15612,"date":"2026-09-29T07:50:12","date_gmt":"2026-09-29T06:50:12","guid":{"rendered":"https:\/\/ventsystems.de\/?p=15612"},"modified":"2026-11-24T11:14:05","modified_gmt":"2026-11-24T10:14:05","slug":"ventilation-control-window-drives","status":"publish","type":"post","link":"https:\/\/ventsystems.de\/en\/lueftungssteuerung-fensterantriebe\/","title":{"rendered":"Ventilation control for window actuators: How to correctly combine buttons, controls and sensors"},"content":{"rendered":"<p class=\"vs-kurzantwort wp-block-paragraph\"><strong>In short:<\/strong> A ventilation control switches several window actuators together \u2013 by switch, radio, timer or sensor \u2013 and closes the windows automatically in rain or wind. The VS-C24-7A control unit, for example, controls up to 7 actuators with 24 V. A ventilation control does not replace a smoke vent control panel.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Learn more: <a href=\"https:\/\/ventsystems.de\/en\/rwa-drives\/\">RWA window drives<\/a>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A ventilation controller determines when and how far motorised windows, fanlights or dome rooflights open. It links the user, the weather and the actuator \u2013 and therefore decides on comfort, energy consumption and protecting the building from rain and storms. Here you\u2019ll learn which components a ventilation controller needs for everyday ventilation and how to combine them sensibly.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Tasks of a ventilation controller<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">For everyday comfort ventilation, a ventilation controller must above all do three things:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Operate:<\/strong> Open and close windows via push button or remote control.<\/li>\n\n\n<li><strong>Supply:<\/strong> Supply the window actuator with the right voltage and sufficient current.<\/li>\n\n\n<li><strong>Protect:<\/strong> Close windows automatically in rain or strong wind.<\/li>\n\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Important: an everyday ventilation controller is not the same as a smoke and heat exhaust ventilation system. SHEV is subject to its own standards and requires an approved SHEV control panel. We explain the difference in the article <a href=\"\/en\/rwa-and-daily-ventilation\/\">Smoke and heat exhaust ventilation (SHEV) and daily ventilation \u2013 what is the difference in planning?<\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Option 1: ventilation push button for 230 V actuators<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The simplest ventilation control is a push button that switches a 230 V window actuator directly. The <a href=\"\/en\/product\/vs-lt-230\/\">VS-LT 230 ventilation button<\/a> is flush-mounted and rated for up to 250 V AC and 10 A. Cables are connected via screwless push-in terminals. Where there is no flush box, the following is suitable: <a href=\"\/en\/product\/vs-lt-a-surface-mounted-ventilation-button\/\">VS-LT-A surface-mount ventilation button<\/a>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This solution is inexpensive and robust but offers no automation: the window stays open until someone closes it.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Option 2: 24 V ventilation controller with remote control and sensors<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">24 V window actuators require a controller with power supply. The <a href=\"\/en\/product\/vs-ls7\/\">VS-C24-7A controller<\/a> converts 230 V AC into 24 V DC and supplies up to 7 A for all connected actuators. It is operated via a button on the unit or a radio remote control (433.92 MHz). It is suitable for all 24 V window actuators from Vent Systems, such as the <a href=\"\/en\/product-category\/chain-drives\/\">Chain actuators<\/a> of the series <a href=\"\/en\/product\/vs-ka\/\">VS-KA<\/a> or the <a href=\"\/en\/product-category\/spindle-drives\/\">Linear actuators<\/a> of the VS-LA series.<\/p>\n\n\n<p class=\"wp-block-paragraph\">You can see how to connect it step by step in the article <a href=\"\/en\/connecting-24v-window-drive-to-230v\/\">Connecting a 24 V window actuator to 230 V mains<\/a>.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Automatic closing in rain and wind<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Only with sensors does the controller become true automatic ventilation. The <a href=\"\/en\/product\/vs-rs\/\">VS-RS rain sensor<\/a> detects precipitation via a contact grid and reports it to the VS-C24-7A so the windows close in time. The <a href=\"\/en\/product\/vs-ws\/\">VS-WRLS-wind-rain-light sensor<\/a> also measures wind strength and brightness \u2013 useful for exposed roof windows or when sun shading runs via the same controller.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">What to consider when planning<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Voltage:<\/strong> Push button and controller must match the actuator\u2019s rated voltage (230 V AC or 24 V DC).<\/li>\n\n\n<li><strong>Current reserve:<\/strong> Add up the rated currents of all actuators on one controller; with the VS-C24-7A a maximum of 7 A in total.<\/li>\n\n\n<li><strong>Cables:<\/strong> Choose cross-sections so that the voltage drop remains low even over long runs.<\/li>\n\n\n<li><strong>Installation location:<\/strong> The VS-C24-7A is intended for indoor installation (IP 50); sensors belong outdoors in an exposed position.<\/li>\n\n\n<li><strong>Specialist contractor:<\/strong> Installation and commissioning by qualified specialists only.<\/li>\n\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">The same 24 V controller can also operate blinds, roller shutters and awnings \u2013 more in the article <a href=\"https:\/\/ventsystems.de\/en\/24v-blind-control\/\">24V blind control<\/a>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Want to motorise an existing tilt window, fanlight or roof window? Find out which actuator fits in our guide <a href=\"\/en\/retrofitting-electric-window-openers\/\">Retrofitting electric window openers<\/a>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">How to connect 24 V and 230 V chain actuators correctly is explained in the guide <a href=\"\/en\/connecting-chain-actuator\/\">Connecting a chain actuator<\/a>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Which control for how many windows?<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Situation<\/th><th>Suitable solution<\/th><th>Note<\/th><\/tr><\/thead><tbody><tr><td>Single 230 V actuator<\/td><td>Ventilation switch <a href=\"\/en\/product\/vs-lt-230\/\">VS-LT-230<\/a><\/td><td>No control unit needed, connection by a qualified electrician<\/td><\/tr><tr><td>1 to 7 windows with 24 V, operated together<\/td><td>steering <a href=\"\/en\/product\/vs-ls7\/\">VS-C24-7A<\/a><\/td><td>Up to 7 actuators, total current consumption below 7 A; radio, rain and wind sensor can be connected<\/td><\/tr><tr><td>More than 7 windows or separate groups<\/td><td>One VS-C24-7A per group<\/td><td>Each group can be operated separately<\/td><\/tr><tr><td>Integration into building management systems<\/td><td>i-series actuators with Modbus<\/td><td>VS-KA-i, VS-LA-i, VS-ZA 600-i, VS-SB 400-i<\/td><\/tr><tr><td>Smoke and heat exhaust ventilation (SHEV)<\/td><td>Smoke control panel from the installer<\/td><td>The VS-C24-7A is not a smoke control panel<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Check in two minutes whether the current consumption is within limits: <a href=\"\/en\/calculate-24v-power-supply-window-actuators\/\">Calculating a 24 V power supply for window actuators<\/a>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Automatic ventilation: by time, temperature or CO\u2082<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A ventilation control can open windows not only at the push of a button, but also automatically according to fixed rules. Three strategies are common in offices, schools and halls:<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li><strong>Time-controlled:<\/strong> Windows open at fixed times, for example for five minutes of intensive airing in every break.<\/li><li><strong>Temperature-controlled:<\/strong> Windows open when the room gets too warm and close when it is warmer outside than inside. This allows the building to cool down at night.<\/li><li><strong>By air quality:<\/strong> A CO\u2082 sensor reports stale air, and the control opens the windows until the values are right again.<\/li><\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">These functions require a control with time and sensor inputs or a connection to the building management system, for example via KNX. Simple controls such as the <a href=\"\/en\/product\/vs-ls7\/\">VS-C24-7A<\/a> are designed for operation via push button, radio and weather protection. The guide provides information on the connection <a href=\"\/en\/integrating-window-drives-into-building-management-systems\/\">Integrating window drives into building management systems<\/a>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Ventilation control or window control?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The terms are often used interchangeably. Window control usually means everything that moves a window actuator, from the push button to the control panel. A ventilation control is designed to bring fresh air into the building regularly and as automatically as possible. The guide gives an overview of all components <a href=\"\/en\/window-control\/\">Window control<\/a>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Suitable control:<\/strong> The <a href=\"\/en\/product\/vs-ls7\/\">VS-C24-7A controller<\/a> It drives up to 7 drives together (depending on the power consumption), plus shutters and roller shutters. More about it: <a href=\"\/en\/automatic-ventilation-of-the-winter-garden\/\">Automatic conservatory ventilation<\/a>.<\/p>\n\n\n<p>Suitable ventilation controls, push buttons and sensors can be found in the category <a href=\"\/en\/product-category\/controls\/\">Window controls<\/a>.<\/p>\n<h2 class=\"wp-block-heading\">Frequently asked questions about ventilation control<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Can a ventilation control also handle SHEV?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">No, not on its own. Smoke extraction requires an approved SHEV control panel. However, many SHEV control panels have a ventilation function, so the same windows can also be used for daily ventilation. More on this in the guide <a href=\"\/en\/rwa-and-daily-ventilation\/\">Smoke ventilation and daily ventilation<\/a>.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">How often should automatic ventilation take place?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">That depends on room use and occupancy. Classrooms and meeting rooms are often aired intensively in every break, halls according to temperature. If in doubt, a CO\u2082 sensor that measures the actual demand helps.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Do the windows close in the event of a power failure?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Not automatically. Without power, most actuators stay in their position. Where windows must close safely in a power failure, a control with emergency power supply is required.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Can a bedroom window ventilate automatically at night and close in the morning?<\/h3>\n\n\n<p class=\"wp-block-paragraph\">Yes, with a timer or a connection to the building services. A rain and wind sensor ensures the window closes when the weather changes. If the window is left open unattended at night, limit the opening width, see <a href=\"\/en\/window-actuator-burglary-protection\/\">Window actuator and burglary protection<\/a>.<\/p>\n\n\n<h3 class=\"wp-block-heading\">Can the window be opened and closed on a timer?<\/h3>\n\n\n<p class=\"wp-block-paragraph\">Yes, via a timer or a control unit or building automation with a time programme. We are happy to clarify which solution suits your control unit.<\/p>\n\n\n<h2 class=\"wp-block-heading\">Conclusion<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">For single windows with a 230 V actuator, a ventilation push button is often enough. If you want to operate several windows conveniently and close them automatically in rain, choose a 24 V ventilation controller with sensor. We\u2019re happy to clarify which combination suits your project in a short <a href=\"\/en\/contact\/\">consultation<\/a>. You\u2019ll find all actuators, controllers and accessories in the <a href=\"https:\/\/ventsystems.de\/en\/\">Vent Systems Shop<\/a>.<\/p>\n\n\n<p class=\"wp-block-paragraph\">The guide explains which components make up a window control <a href=\"\/en\/window-control\/\">Window control<\/a>. For push buttons and controls on the wall there is the <a href=\"\/en\/product\/vs-ad-c24\/\">On-board charger VS-AD C24<\/a> and the <a href=\"\/en\/product\/vs-ad-lt\/\">VS-AD LT surface-mounted housing<\/a>.<\/p>\n\n\n\n\n<p class=\"wp-block-paragraph\">How big the power supply or control unit must be is shown in the guide <a href=\"\/en\/calculate-24v-power-supply-window-actuators\/\">Calculating a 24 V power supply for window actuators<\/a>.<\/p>\n\n\n\n\n\n<p class=\"wp-block-paragraph\">See also in the glossary: <a href=\"\/en\/dictionary\/temperature-sensor\/\">Temperature sensor<\/a> \u00b7 <a href=\"\/en\/dictionary\/co2-sensor\/\">CO\u2082 sensor<\/a> \u00b7 <a href=\"\/en\/dictionary\/cross-ventilation\/\">Cross ventilation<\/a><\/p>","protected":false},"excerpt":{"rendered":"<p>Kurz gesagt: Eine L\u00fcftungssteuerung schaltet mehrere Fensterantriebe gemeinsam \u2013 per Taster, Funk, Zeitprogramm oder Sensor \u2013 und schlie\u00dft die Fenster bei Regen oder Wind automatisch. Die Steuerung VS-C24-7A steuert zum Beispiel bis zu 7 Antriebe mit 24 V. Eine L\u00fcftungssteuerung ersetzt keine RWA-Zentrale. Mehr dazu: RWA-Fensterantriebe. Eine L\u00fcftungssteuerung bestimmt, wann und wie weit elektrisch angetriebene [&hellip;]<\/p>\n","protected":false},"author":9,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1958],"tags":[],"class_list":["post-15612","post","type-post","status-publish","format-standard","hentry","category-lueftung-gebaeudeautomation"],"acf":[],"_links":{"self":[{"href":"https:\/\/ventsystems.de\/en\/wp-json\/wp\/v2\/posts\/15612","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ventsystems.de\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/ventsystems.de\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/ventsystems.de\/en\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/ventsystems.de\/en\/wp-json\/wp\/v2\/comments?post=15612"}],"version-history":[{"count":18,"href":"https:\/\/ventsystems.de\/en\/wp-json\/wp\/v2\/posts\/15612\/revisions"}],"predecessor-version":[{"id":18527,"href":"https:\/\/ventsystems.de\/en\/wp-json\/wp\/v2\/posts\/15612\/revisions\/18527"}],"wp:attachment":[{"href":"https:\/\/ventsystems.de\/en\/wp-json\/wp\/v2\/media?parent=15612"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ventsystems.de\/en\/wp-json\/wp\/v2\/categories?post=15612"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ventsystems.de\/en\/wp-json\/wp\/v2\/tags?post=15612"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}