{"id":15739,"date":"2026-10-06T14:55:17","date_gmt":"2026-10-06T13:55:17","guid":{"rendered":"https:\/\/ventsystems.de\/windowmaster-antrieb-ersetzen\/"},"modified":"2026-11-21T14:05:38","modified_gmt":"2026-11-21T13:05:38","slug":"replacing-windowmaster-actuator","status":"publish","type":"post","link":"https:\/\/ventsystems.de\/en\/windowmaster-antrieb-ersetzen\/","title":{"rendered":"Replacing WindowMaster actuators: alternatives to WMX and WMU"},"content":{"rendered":"<p>Does a WindowMaster actuator need to be replaced? There are matching Vent Systems alternatives for the chain actuators of the WMX and WMU series. The table compares the data directly.<\/p>\n<h2>Which Vent Systems drive replaces which WindowMaster actuator?<\/h2><table><thead><tr><th>WindowMaster actuator<\/th><th>Data (manufacturer)<\/th><th>Alternative from Vent Systems<\/th><th>Note<\/th><\/tr><\/thead><tbody><tr><td>WMX 503 (concealed)<\/td><td>24 V, 150 N, stroke 50\u2013250 mm, IP32<\/td><td><a href=\"\/en\/product\/vs-cka-300\/\">VS-CKA 300 built-in chain drive<\/a><\/td><td>concealed installation, stroke up to 1000 mm<\/td><\/tr><tr><td>WMX 504<\/td><td>24 V, 150 N, stroke 50\u2013250 mm, surface-mounted<\/td><td><a href=\"\/en\/product\/vs-ka\/\">VS-KA 250 N, 24 V<\/a><\/td><td>suitable alternative<\/td><\/tr><tr><td>WMX 526<\/td><td>24 V, 150 N, stroke up to 500 mm, 7 mm\/s<\/td><td><a href=\"\/en\/product\/vs-ka\/\">VS-KA 250 N, 24 V<\/a><\/td><td><\/td><\/tr><tr><td>WMX 804 \/ WMX 826<\/td><td>24 V, SHEV version, up to 200 N<\/td><td><a href=\"\/en\/product\/vs-ka\/\">VS-KA 250 N, 24 V<\/a><\/td><td>also suitable for SHEV<\/td><\/tr><tr><td>WMU 8xx (e.g. WMU 862, 885)<\/td><td>24 V, up to 1500 N, heavy roof and fa\u00e7ade windows<\/td><td><a href=\"\/en\/product\/vs-ka\/\">VS-KA 600 N \/ 1500 N<\/a> or <a href=\"\/en\/product\/vs-ka-2500\/\">VS-KA 2500<\/a><\/td><td><\/td><\/tr><\/tbody><\/table>\n<p style=\"font-size:13px;color:#5b6b74\"><em>Information on third-party products is based on publicly available manufacturer documents (as of 2026), without guarantee. WindowMaster is a trademark of its owner; Vent Systems is not affiliated with the manufacturer. Please check installation dimensions, force and control before replacing.<\/em><\/p>\n<h2>How do I find the right alternative to my WindowMaster actuator?<\/h2>\n<p>Read the type, force and stroke from the type plate. For the light WMX actuators (150\u2013200 N), the VS-KA with 250 N is suitable; for the powerful WMU actuators, the VS-KA with 600 or 1500 N or the VS-KA 2500. WindowMaster actuators operate at \u00b124 V \u2013 Vent Systems drives can be controlled this way; MotorLink\u00ae functions are not available.<\/p>\n<h2>What to look out for when replacing a WindowMaster actuator<\/h2>\n<p>WindowMaster offers concealed and surface-mounted chain actuators. The WMX 503 sits concealed in the profile and is replaced by the VS-CKA 300 built-in chain actuator. The surface-mounted WMX 504, WMX 526, WMX 804 and WMX 826 are replaced by the VS-KA with 250 N; for the more powerful WMU range the table lists the VS-KA with 600 or 1500 N. For approved NSHEV units according to EN 12101-2, replacing the actuator can void the approval \u2013 only replace after consulting the window manufacturer or an expert.<\/p>\n<p>All points at a glance: <a href=\"\/en\/replacing-window-drives\/\">Checklist for replacing window actuators<\/a><\/p>\n<h2>Does the replacement drive work with my WindowMaster control unit?<\/h2>\n<p>Yes, provided the control unit switches conventionally via \u00b124 V (polarity reversal) and can handle the current consumption. Digital MotorLink\u00ae functions such as position feedback are not available with a third-party drive.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Mounting:<\/strong> We supply standard brackets, special brackets on request. If in doubt, send us a photo of the mounting via <a href=\"\/en\/send-a-photo\/\">Send a photo<\/a>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Frequently asked questions<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Which actuator replaces the WindowMaster WMX 504 or WMX 526?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The VS-KA with 250 N and 24 V. It pushes harder than the 150 N of the WMX actuators.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Is there a replacement for the concealed WMX 503?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Yes, the VS-CKA 300 concealed chain actuator, with stroke up to 1000 mm.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">What do I use for the powerful WMU actuators?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Depending on force, the VS-KA with 600 N or 1500 N or the VS-KA 2500.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">How quickly is the replacement available?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">We ship stock items from Hamburg within 24 hours. Send us a photo of the rating plate first and we'll tell you the right actuator.<\/p>\n\n\n<h2>Download the replacement table as a PDF<\/h2>\n<p>Comparisons for all six manufacturers (GEZE, Aum\u00fcller, Kingspan STG, D+H, WindowMaster, HAUTAU) can be found in our <a href=\"https:\/\/ventsystems.de\/wp-content\/uploads\/2026\/10\/Austauschtabelle-Fensterantriebe-9-Hersteller-Vent-Systems-10-2026.pdf\" target=\"_blank\" rel=\"noopener\"><strong>replacement table for window drives (PDF)<\/strong><\/a> and in the guide <a href=\"\/en\/replacing-window-drives\/\">Replacing window drives<\/a>.<\/p>\n\n<p class=\"wp-block-paragraph\">See also in the glossary: <a href=\"\/en\/dictionary\/position-feedback\/\">Position feedback<\/a><\/p>\n\n\n<h2>Not sure which drive fits?<\/h2>\n<p>Send us a photo of the type plate and the window. We will name the right Vent Systems actuator \u2013 stock items are shipped from Hamburg within 24 hours. <a href=\"\/en\/contact\/\">To the contact form<\/a>.<\/p>\n<p><em>D+H, WindowMaster and HAUTAU are trademarks of their respective owners. Vent Systems is not affiliated with these manufacturers. The manufacturer data is taken from publicly available data sheets (as of October 2026) and is for comparison only.<\/em><\/p>\n<p><strong>Detailed comparison:<\/strong> <a href=\"\/en\/windowmaster-wml-825-alternative\/\">Alternative to the WindowMaster WML 825 for VELUX windows<\/a><\/p>\n\n<p class=\"has-small-font-size wp-block-paragraph\"><em>Note: The brand and product names mentioned belong to their respective owners. They are used here only to indicate technical compatibility. Vent Systems is not affiliated with these manufacturers; only Vent Systems\u2019 own actuators are offered.<\/em><\/p>\n\n\n<p class=\"wp-block-paragraph\">More manufacturers and types at a glance: <a href=\"https:\/\/ventsystems.de\/en\/window-actuator-replacement-table\/\">replacement table for window actuators<\/a>.<\/p>","protected":false},"excerpt":{"rendered":"<p>Matching Vent Systems alternatives for WindowMaster WMX 503, 504, 526, 804, 826 and WMU \u2013 with a technical comparison.<\/p>","protected":false},"author":9,"featured_media":2288,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1959],"tags":[],"class_list":["post-15739","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-antriebstechnik"],"acf":[],"_links":{"self":[{"href":"https:\/\/ventsystems.de\/en\/wp-json\/wp\/v2\/posts\/15739","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ventsystems.de\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/ventsystems.de\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/ventsystems.de\/en\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/ventsystems.de\/en\/wp-json\/wp\/v2\/comments?post=15739"}],"version-history":[{"count":20,"href":"https:\/\/ventsystems.de\/en\/wp-json\/wp\/v2\/posts\/15739\/revisions"}],"predecessor-version":[{"id":18365,"href":"https:\/\/ventsystems.de\/en\/wp-json\/wp\/v2\/posts\/15739\/revisions\/18365"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ventsystems.de\/en\/wp-json\/wp\/v2\/media\/2288"}],"wp:attachment":[{"href":"https:\/\/ventsystems.de\/en\/wp-json\/wp\/v2\/media?parent=15739"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ventsystems.de\/en\/wp-json\/wp\/v2\/categories?post=15739"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ventsystems.de\/en\/wp-json\/wp\/v2\/tags?post=15739"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}