{"id":15740,"date":"2026-10-06T14:55:24","date_gmt":"2026-10-06T13:55:24","guid":{"rendered":"https:\/\/ventsystems.de\/hautau-kettenantrieb-ersetzen\/"},"modified":"2026-11-21T14:05:42","modified_gmt":"2026-11-21T13:05:42","slug":"replacing-hautau-chain-actuator","status":"publish","type":"post","link":"https:\/\/ventsystems.de\/en\/hautau-kettenantrieb-ersetzen\/","title":{"rendered":"Replacing HAUTAU chain drives: alternatives to SKA and EKA"},"content":{"rendered":"<p>Is a HAUTAU chain drive defective? There are matching Vent Systems alternatives for the common 24 V and 230 V chain drives. The table gives an overview.<\/p>\n<h2>Which Vent Systems drive replaces which HAUTAU drive?<\/h2><table><thead><tr><th>HAUTAU drive<\/th><th>Data (manufacturer)<\/th><th>Alternative from Vent Systems<\/th><th>Note<\/th><\/tr><\/thead><tbody><tr><td>SKA 20 comfort drive<\/td><td>24 V, approx. 200 N, for ventilation and SHEV<\/td><td><a href=\"\/en\/product\/vs-ka\/\">VS-KA 250 N, 24 V<\/a><\/td><td><\/td><\/tr><tr><td>SKA 50 (e.g. SKA 50-500, -600, -700)<\/td><td>24 V, stroke 500\u2013700 mm, bottom-hung, top-hung, side-hung and roof windows, SHEV<\/td><td><a href=\"\/en\/product\/vs-ka\/\">VS-KA 600 N, 24 V<\/a><\/td><td><\/td><\/tr><tr><td>EKA 20 \/ EKA 30<\/td><td>230 V, ventilation<\/td><td><a href=\"\/en\/product\/vs-ka\/\">VS-KA 250 N or 400 N, 230 V<\/a><\/td><td><\/td><\/tr><\/tbody><\/table>\n<p style=\"font-size:13px;color:#5b6b74\"><em>Information on third-party products is based on publicly available manufacturer documents (as of 2026), without guarantee. HAUTAU is a trademark of its owner; Vent Systems is not affiliated with the manufacturer. Please check installation dimensions, force and control before replacing.<\/em><\/p>\n<h2>How do I find the right alternative to my HAUTAU drive?<\/h2>\n<p>At HAUTAU, SKA stands for 24 V and EKA for 230 V chain drives; the number indicates the size, and the second number often the stroke (e.g. SKA 50-600). Read the force and stroke from the type plate and choose the VS-KA with the same or higher force. For heavy roof windows, the <a href=\"\/en\/product\/vs-ka-2500\/\">VS-KA 2500<\/a> with IP66 offers additional reserves.<\/p>\n<h2>What to look out for when replacing a Hautau chain actuator<\/h2>\n<p>With Hautau, voltage is what matters most: the SKA 20 comfort drive and SKA 50 run on 24 V and are replaced by the 24 V VS-KA with 250 or 600 N. The EKA 20 and EKA 30 are 230 V actuators \u2013 here choose the 230 V VS-KA with 250 or 400 N. For approved NSHEV units according to EN 12101-2, replacing the actuator can void the approval \u2013 only replace after consulting the window manufacturer or an expert.<\/p>\n<p>All points at a glance: <a href=\"\/en\/replacing-window-drives\/\">Checklist for replacing window actuators<\/a><\/p>\n<h2>Does the replacement also work without the HAUTAU bus?<\/h2>\n<p>Yes. HAUTAU drives can be switched as standard via polarity reversal (24 V) or phase control (230 V) \u2013 just like Vent Systems drives. Comfort drive functions such as bus connection and app configuration are not available with a third-party drive.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Mounting:<\/strong> We supply standard brackets, special brackets on request. If in doubt, send us a photo of the mounting via <a href=\"\/en\/send-a-photo\/\">Send a photo<\/a>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Frequently asked questions<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Which actuator replaces the HAUTAU SKA 50?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The VS-KA with 600 N and 24 V. Take the stroke from the rating plate, e.g. 500, 600 or 700 mm.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Is there a replacement for HAUTAU EKA 20 and EKA 30 with 230 V?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Yes. For the EKA 20 the VS-KA with 250 N in 230 V fits, for the EKA 30 the VS-KA with 400 N in 230 V.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Do the HAUTAU brackets fit the new actuator?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">No, the brackets don't fit 1:1. Use the Vent Systems brackets and check the installation dimensions in the datasheet.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">How quickly is the replacement available?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">We ship stock items from Hamburg within 24 hours. Send us a photo of the rating plate first and we'll tell you the right actuator.<\/p>\n\n\n<h2>Download the replacement table as a PDF<\/h2>\n<p>Comparisons for all six manufacturers (GEZE, Aum\u00fcller, Kingspan STG, D+H, WindowMaster, HAUTAU) can be found in our <a href=\"https:\/\/ventsystems.de\/wp-content\/uploads\/2026\/10\/Austauschtabelle-Fensterantriebe-9-Hersteller-Vent-Systems-10-2026.pdf\" target=\"_blank\" rel=\"noopener\"><strong>replacement table for window drives (PDF)<\/strong><\/a> and in the guide <a href=\"\/en\/replacing-window-drives\/\">Replacing window drives<\/a>.<\/p>\n<h2>Not sure which drive fits?<\/h2>\n<p>Send us a photo of the type plate and the window. We will name the right Vent Systems actuator \u2013 stock items are shipped from Hamburg within 24 hours. <a href=\"\/en\/contact\/\">To the contact form<\/a>.<\/p>\n<p><em>D+H, WindowMaster and HAUTAU are trademarks of their respective owners. Vent Systems is not affiliated with these manufacturers. The manufacturer data is taken from publicly available data sheets (as of October 2026) and is for comparison only.<\/em><\/p>\n\n<p class=\"has-small-font-size wp-block-paragraph\"><em>Note: The brand and product names mentioned belong to their respective owners. They are used here only to indicate technical compatibility. Vent Systems is not affiliated with these manufacturers; only Vent Systems\u2019 own actuators are offered.<\/em><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>In brief:<\/strong> For HAUTAU chain actuators, Vent Systems offers suitable alternatives: the VS-KA with 250 N in 24 V for the SKA 20, the VS-KA with 600 N in 24 V for the SKA 50, and the VS-KA with 250 or 400 N in 230 V for the EKA 20 and EKA 30. The new actuator should have at least the force of the old one, and you take the stroke from the rating plate.<\/p>\n\n\n<p class=\"wp-block-paragraph\">More manufacturers and types at a glance: <a href=\"https:\/\/ventsystems.de\/en\/window-actuator-replacement-table\/\">replacement table for window actuators<\/a>.<\/p>","protected":false},"excerpt":{"rendered":"<p>Matching Vent Systems alternatives for HAUTAU chain drives SKA 20, SKA 50, EKA 20 and EKA 30.<\/p>","protected":false},"author":9,"featured_media":2288,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1959],"tags":[],"class_list":["post-15740","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-antriebstechnik"],"acf":[],"_links":{"self":[{"href":"https:\/\/ventsystems.de\/en\/wp-json\/wp\/v2\/posts\/15740","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ventsystems.de\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/ventsystems.de\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/ventsystems.de\/en\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/ventsystems.de\/en\/wp-json\/wp\/v2\/comments?post=15740"}],"version-history":[{"count":20,"href":"https:\/\/ventsystems.de\/en\/wp-json\/wp\/v2\/posts\/15740\/revisions"}],"predecessor-version":[{"id":18366,"href":"https:\/\/ventsystems.de\/en\/wp-json\/wp\/v2\/posts\/15740\/revisions\/18366"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ventsystems.de\/en\/wp-json\/wp\/v2\/media\/2288"}],"wp:attachment":[{"href":"https:\/\/ventsystems.de\/en\/wp-json\/wp\/v2\/media?parent=15740"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ventsystems.de\/en\/wp-json\/wp\/v2\/categories?post=15740"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ventsystems.de\/en\/wp-json\/wp\/v2\/tags?post=15740"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}