Introductory offer

VS-SA 2500

Strong spindle drives for the heavy-light domes

Preis: nur auf Anfrage

Lieferzeit ca. 5 - 6 Wochen (Express auf Anfrage)

Spindle drives VS-SA – and The uncompromising force packages for heavy skylights and RWA applications
Thanks to its huge reserves of power and the high-precision, self-locking spindle technique you can open and close wings with several hundred kilograms of weight easily – year, maintenance-free and virtually silent.
Technical Highlights – bar directly above the selection can be configured:

Push and pull force: 2.500 N
Stroke of 100 mm to 1,000 mm (continuously adjustable)

Additional information

Stroke length

, , , , , , , , ,

Product safety

Safety instructions

Read all safety warnings, instructions, illustrations and technical data in this product carefully. Failure to observe the following operating instructions can lead to electric shock, fire and / or serious injury. Save all warnings and instructions for future Reference.

Intended Use

– Designed for Opening and Closing the Windows and louvers on the building facades and roofs

– Operating voltage: 24 V DC (-15 %/+25 %)

– Suitable for smoke extraction and daily comfort ventilation

– Only for indoor installation

Scope of delivery

Chain drive

– Different console component are available as optional accessories for specific types of Windows available.

Requirements for qualification of personnel

All installation, wiring, commissioning and maintenance of window actuators may only be operated by trained and qualified personnel. Untrained personnel access to all areas of the Work is strictly prohibited.

Pre-installation and Device selection

– Turn on the window-opener, to check it for any transit damage

– Make sure that the load capacity of the selected model corresponds to the actual window weight and wind pressure, and thus, all of the operating requirements

– Check the stability of the window frame and the hinges to ensure that you keep the operating loads

– Always use Original mounting brackets and fasteners. For aluminium window frames, rivets, or

Through-bolts are recommended

self-cutting should be avoided screws

Requirements for electrical safety

– Power window actuator needs to ensure a stable operating voltage of 24 V DC (-15 %/+25%).

Voltage fluctuations outside of this range can Board the device to malfunction or damage to the control

lead

– Use according to the technical standard is sufficiently dimensioned cable to minimize voltage drop.

Intended Use

– The control unit should have an automatic shut-off function, which is activated as soon as the chain-drive its fully

open Position has been reached. As a result, the power supply is interrupted at the end of the Stroke

– Before cleaning, maintenance or Troubleshooting of the main power supply to work, always disconnect

Safety precautions for the Installation

– For Windows, which are installed in a height of 2.5 meters, must be reliable anti-trap devices. In

public areas should also be an infrared safety sensor installed. For floor-standing window safety ropes are

and fall protection is required

– All automatic Windows, must wear a clearly visible place a clearly visible warning "risk of entrapment"

– Keep the operating area of the window is clear of obstacles. Manual controls must be installed so that the

Movement of the window can be directly observed

Maintenance and cleaning

– All maintenance work must be carried out in completely the device is switched off.

– A routine Review of the power cable and rails should be done at least once a year. The detection of

Abnormalities discontinue use immediately. Repairs may only parts of the AF-certified technicians using original

be carried out. Unauthorized disassembly is strictly prohibited.

– Use a soft, dry cloth to remove any dust or dirt from the surface. Do not use

Cleaning agents or solvents

Technical Data

  • Compact Design
  • Flexible Hub/Power/Speed Setting
  • Electronic Overload Shutdown Protection
  • Automatic stop protection in the case of obstacle
  • Flexible mounting brackets for Installation
  • Low-noise operation and a smooth, stable running
  • The locking force static movement is 4000N
Supply 24V DC +/-15%
Performance 5A
Pressure force 2500N
Degree of protection IP 44
Stroke length 100/200/300/400/500/600/800/900/1000 mm
Running speed 25mm/s
Life 10000 cycles
Temperature range -20°С... +60°С
Temperature stability B300
Housing Plastic

Scope of delivery

If you need further information on delivery? Please contact us, we will respond immediately to help!

0
    0
    Your Shopping Cart
    Your shopping cart is emptyBack to the Shop