VS-KA 2500 heavy-duty chain drive

VS-KA 2500 heavy-duty chain drive to open heavy sashes, 2500N, 24V

290,00 350,00 

Delivery time about 5 - 6 weeks (Express on request)

Quantity discounts and individual discounts for registered users is possible on request.

VS-KA 2500 heavy-duty chain drive: one of the strongest – if not the strongest – chain drive in our range, designed specifically to open very heavy and large casement windows.

As a waterproof double-chain drive (IP66) with a thrust force of 2500 N, the VS-KA 2500 easily copes with large and heavy glazing, where conventional chain drives are pushed to their limits. The two chains provide extra stability and a long service life, even under continuous load.

The drive operates at 24 V with a running speed of 8 mm/s and is designed for a temperature range of -20°C to +75°C. The stroke length is up to 1200 mm, available from us in lengths of 300, 400, 500, and 1000 mm. Other lengths are available on request.

Thanks to its IP66 protection rating, the VS-KA 2500 is also suitable for outdoor use as well as for demanding smoke and heat extraction systems (RWA) – wherever high forces, weather protection, and a long service life are required.

Additional information

Stroke length

, , ,

Product safety

Safety instructions

Carefully read all safety instructions, directions, illustrations and technical data supplied with this product. Failure to follow the operating instructions below can result in electric shock, fire, and serious injury. Keep all warnings and instructions for future reference.

Intended Use

– Designed for Opening and Closing the Windows and louvers on the building facades and roofs

– Operating voltage: 24 V DC (-15 %/+25 %)

– Suitable for smoke extraction and daily comfort ventilation

– Only for indoor installation

Scope of delivery

Chain drive

Different bracket components are available as optional accessories for specific window types.

Requirements for qualification of personnel

All installation, wiring, commissioning and maintenance of window actuators may only be operated by trained and qualified personnel. Untrained personnel access to all areas of the Work is strictly prohibited.

Pre-installation and Device selection

– Turn on the window-opener, to check it for any transit damage

– Make sure that the load capacity of the selected model corresponds to the actual window weight and wind pressure, and thus, all of the operating requirements

– Check the stability of the window frame and the hinges to ensure that you keep the operating loads

– Always use Original mounting brackets and fasteners. For aluminium window frames, rivets, or

Through-bolts are recommended

self-cutting should be avoided screws

Requirements for electrical safety

– Power window actuator needs to ensure a stable operating voltage of 24 V DC (-15 %/+25%).

Voltage fluctuations outside of this range can Board the device to malfunction or damage to the control

lead

– Use according to the technical standard is sufficiently dimensioned cable to minimize voltage drop.

Intended Use

– The control unit should have an automatic shut-off function, which is activated as soon as the chain-drive its fully

open Position has been reached. As a result, the power supply is interrupted at the end of the Stroke

– Before cleaning, maintenance or Troubleshooting of the main power supply to work, always disconnect

Safety precautions for the Installation

– For Windows, which are installed in a height of 2.5 meters, must be reliable anti-trap devices. In

public areas should also be an infrared safety sensor installed. For floor-standing window safety ropes are

and fall protection is required

– All automatic Windows, must wear a clearly visible place a clearly visible warning "risk of entrapment"

– Keep the operating area of the window is clear of obstacles. Manual controls must be installed so that the

Movement of the window can be directly observed

Maintenance and cleaning

– All maintenance work must be carried out in completely the device is switched off.

– A routine Review of the power cable and rails should be done at least once a year. The detection of

Abnormalities discontinue use immediately. Repairs may only parts of the AF-certified technicians using original

be carried out. Unauthorized disassembly is strictly prohibited.

– Use a soft, dry cloth to remove any dust or dirt from the surface. Do not use

Cleaning agents or solvents

Technical Data

Voltage: 24 V
Thrust force: 2500 N
Power: 4.5 A
Stroke: 100-1200 mm (available from us: 300 / 400 / 500 / 1000 mm)
Running speed: 8 mm/s
Temperature range: -20°C to +75°C
Protection class: IP66 (waterproof)
Design: Double Chain Drive

Flexible stroke/force/speed setting
Double link chain / stainless steel chain available
Automatic stop protection in case of an obstacle
Flexible mounting brackets for installation
Low-noise operation and smooth running
Locking force under static load: 5000 N

Scope of delivery

Drive VS-KA 2500 with fixing consoles

0
0
Your Shopping Cart
Your shopping cart is emptyBack to the Shop