VS-SB 400-i chain drive with side bow chain

Smart 400 N chain drive with side bow chain, for a larger opening angle.

143,00 175,00 

Delivery time about 5 - 6 weeks (Express on request)

Quantity discounts and individual discounts for registered users is possible on request.

VS-SB 400-i chain drive with side bow chain: a smart, Modbus-integrated 400 N drive for automated window and ventilation control.

The VS-SB 400-i can be operated in simple standalone mode, in a synchronized group with multiple drives, or as an addressable drive integrated into a network control center via Modbus protocol. This makes it particularly suitable for applications where multiple windows need to be controlled in a coordinated way.

The drive operates at 24 V DC with a running speed of approx. 10 mm/s and achieves a service life of over 10,000 cycles. The stroke is available in lengths from 400 to 1000 mm, and the clamping force is 3500 N.

The VS-SB 400-i is designed for indoor use (protection class IP32) and is suitable for smoke extraction as well as daily comfort ventilation of windows and ventilation grilles.

Additional information

Stroke length

, , , , , ,

Product safety

Safety instructions

Carefully read all safety instructions, directions, illustrations and technical data supplied with this product. Failure to follow the operating instructions below can result in electric shock, fire, and serious injury. Keep all warnings and instructions for future reference.

Intended Use

– Designed for Opening and Closing the Windows and louvers on the building facades and roofs

– Operating voltage: 24 V DC (-15 %/+25 %)

– Suitable for smoke extraction and daily comfort ventilation

– Only for indoor installation

Scope of delivery

Chain drive

Different bracket components are available as optional accessories for specific window types.

Requirements for qualification of personnel

All installation, wiring, commissioning and maintenance of window actuators may only be operated by trained and qualified personnel. Untrained personnel access to all areas of the Work is strictly prohibited.

Pre-installation and Device selection

– Turn on the window-opener, to check it for any transit damage

– Make sure that the load capacity of the selected model corresponds to the actual window weight and wind pressure, and thus, all of the operating requirements

– Check the stability of the window frame and the hinges to ensure that you keep the operating loads

– Always use Original mounting brackets and fasteners. For aluminium window frames, rivets, or

Through-bolts are recommended

self-cutting should be avoided screws

Requirements for electrical safety

– Power window actuator needs to ensure a stable operating voltage of 24 V DC (-15 %/+25%).

Voltage fluctuations outside of this range can Board the device to malfunction or damage to the control

lead

– Use according to the technical standard is sufficiently dimensioned cable to minimize voltage drop.

Intended Use

– The control unit should have an automatic shut-off function, which is activated as soon as the chain-drive its fully

open Position has been reached. As a result, the power supply is interrupted at the end of the Stroke

– Before cleaning, maintenance or Troubleshooting of the main power supply to work, always disconnect

Safety precautions for the Installation

– For Windows, which are installed in a height of 2.5 meters, must be reliable anti-trap devices. In

public areas should also be an infrared safety sensor installed. For floor-standing window safety ropes are

and fall protection is required

– All automatic Windows, must wear a clearly visible place a clearly visible warning "risk of entrapment"

– Keep the operating area of the window is clear of obstacles. Manual controls must be installed so that the

Movement of the window can be directly observed

Maintenance and cleaning

– All maintenance work must be carried out in completely the device is switched off.

– A routine Review of the power cable and rails should be done at least once a year. The detection of

Abnormalities discontinue use immediately. Repairs may only parts of the AF-certified technicians using original

be carried out. Unauthorized disassembly is strictly prohibited.

– Use a soft, dry cloth to remove any dust or dirt from the surface. Do not use

Cleaning agents or solvents

Technical Data

Nominal voltage: 24 V DC (-15%/+25%)
Rated Current: 1.5 A
Connector: 6 x 0.75 mm2
Shutdown: electronic
Stroke length: approx. 400-1000 mm
Push force/pull force: 400 N
Clamping Force: 3500 N
Running speed: approx. 10 mm/s
Service Life: > 10,000 Cycles
Ambient temperature: -15°C to +70°C
Degree of protection: IP32 (indoor installation)
Control: single mode, synchronous operation, or addressable via Modbus

Scope of delivery

Chain drive VS-SB 400-i. Mounting brackets are available separately as optional accessories for the respective window type.