Updated: 21.11.2026
The Corrosivity category describes how strongly the environment attacks metal. It ranges from C1 (very low) to C5 (very high), plus CX (extreme). It is based on DIN EN ISO 9223 and DIN EN ISO 12944-2.
The categories at a glance
| Category | Exposure | Typical indoor spaces (examples) |
|---|---|---|
| C1 | very low | heated rooms with dry, clean air, e.g. offices, schools |
| C2 | low | unheated buildings with occasional condensation, e.g. warehouses, sports halls |
| C3 | mäßig | rooms with high humidity and some air pollution, e.g. food production, laundries |
| C4 | high | chemical plants, swimming pools |
| C5 | very high | buildings with almost permanent condensation and heavy pollution |
| CX | extreme | special cases with extreme exposure |
What does this mean for window actuators?
Most window actuators are built for dry indoor spaces, i.e. for C1 and C2. In C3 and C4, moisture and pollutants attack chains, spindles, screws and housings. There, actuators should be enclosed (IP65 or higher), have metal parts made of A4 stainless steel, and the control unit should be located outside the exposed room.
For stainless steel, the C category alone is not enough: the grade required follows from the corrosion resistance class under DIN EN 1993-1-4 – see Stainless steel A2 and A4.
Indoor pool = C4
In indoor pools, warm, humid air containing chlorine compounds condenses on cool building parts and accumulates there. That is why swimming pools are classed as category C4. What matters when replacing actuators there is shown on the page Window actuators for indoor pools.
Related terms
Not sure which actuator fits? Send us a photo of the rating plate via Send a photo or use the actuator finder.
Related terms: condensation · Dome rooflight · Protection class (IP code)